titrant

Titrant is a substance added from the burette. Titrant used and reaction that proceeds usually defines name of the titration - like acid-base (or alkalimetric) titration if we use strong acid (or strong base) as a titrant, or redox when the reaction that proceeds is of a redox type. Name can be also much more specific - like permanganometric titration (also known as manganometry or permanganometry) when titrant is potassium permanganate.

titration fraction (or titration percentage)

Titration fraction tells us how far we have proceeded with the titration. At the equivalence point we have added stoichiometric amount of titrant and titration fraction equals 1 (or 100%, when it is expressed as titration percentage).

It may seem that more convenient will be to use titrant volume to measure titration progres. That's not a case. For example it is much easier to say "pH at 50% titration equals pKa of monoprotic weak acid" then to calculate each time volume of titrant added to get to the same point.

Note that in the case of polyprotic acids 100% titration may either mean that only first proton was fully neutralised, or that acid was completely neutralised. Thus depending on the definition used fully titrated phosphoric acid is titrated either 100% or 300%. We will use the latter number throughout the site.

titration equivalence point

Equivalence point is where the titration should really end - titration fraction equals exactly 1, we have added stoichiometric amount of titrant to titrated substance. That's not necessarily where we end titration.

titration end point

End point is where the titration ends in practice. The closer the end point to the equivalence point the better, but it is often not easy to find a good method of equivalence point detection. However, very often we can easily spot a point very close to the equivalence point - and that's where the end point will be.

For example in alkalimetric titration of a strong acid with a strong base equivalence point is at pH 7.00, but the most popular and convenient indicator used - phenolphthalein - starts to change color at pH slightly above 8 (in the lab practice change can be observed much closer to 9). In permanganate titrations we don't use any special indicator, as the permanganate solution is strongly colored and excess of titrant added is easily visible (especially if we put white paper sheet behind the flask). In both cases we can't see the color without adding small excess of titrant which introduces small positive error in the titration As long as this error is in the same range as the burette precision (and precision with which we can read the volume) we can safely ignore it.

titration curve

Titration curve is a plot of changes of some selected solution property during titration. Property selected depends on the titration. In the case of alkalimetric titration we look for the changes in solution pH, in the case of complexometric titration we will usually trace changes in metal concentration (using its logarithm or minus logarithm on the plot, as concentration can change even 1010 times), during redox titrations we are interested in the redox potential in the solution and so on.

Most titration curves have the same shape - plateau in the first part, sharp rise (or fall) near equivalence point (inflection point of the curve), followed by the second flat part. The most important part of the curve is the one where the changes are the fastest - close to the inflection point. Thanks to the fact that changes occur so fast there, and are so large, they are usually easily detectable. That in turn helps us detect titration end point.

تعاريف أساسيه في titration Acetic-acid-titration-curve

Acetic acid titrated with sodium hydroxide. Titration curve generated with BATE - pH calculator.

Sometimes - depending on the titration type and solution property selected - titration curve can have different shape. For example if we use conductometry to localize end point of alkalimetric titration, we measure not the solution pH, but its conductance - and titration curves are in this case V shaped.